1. Generally
The completed checklist becomes part of ALBERT’s order documentation.
For the correct exchange of information, you as customer, receive all the information you need to correctly assess your application. At the same time you have to ask for all the necessary criteria.
The operator must ensure:
- Compliance with the performance of the lifting gear or the lifting system
- A potentially explosive atmosphere always has to be avoided. If this is not possible, the danger of explosion has to be reduced
- Compliance with the operating and maintenance instructions for the corresponding screw jack
2. Explosion application areas for screw jacks– Device group and Category (Zone)
2a. Device group I:
Devices for use mining/underground operations as well as open-caste.
| Category | Requirement | Availability |
|---|---|---|
| M1 | Very high safety |
Not available |
| M2 | High safety | Not available |
2b. Device group II:
Devices for use in other areas which may be endangered by an explosive atmosphere.
| Category | Danger | Requirement | Zone | Group of substances | Availability |
|---|---|---|---|---|---|
| 1 | Constantly -frequently - ore over a longer period of time | Very high safety |
Zone 0 | G Gas | Not available |
| Zone 20 | D Dust | ||||
| 2 | Occasionally | High safety | Zone 1 | G Gas | Available |
| Zone 21 | D Dust | ||||
| 3 | Rarely and briefly | Normal safety | Zone 2 | G Gas | Available |
| Zone 22 | D Dust |
3 + 4. Temperature classes and Explosion groups
| Temperature class | Max. surface temperature | Max. ignition temperature of the substance |
Explosion group | Availability | ||
|---|---|---|---|---|---|---|
| IIA | IIB | IIC | ||||
| T1 | 450°C | >450°C | Propan | Watergas | Hydrogen | Available |
| T2 | 300°C | >300°C | Liquified gas | Ethylene | Acetylene | |
| T3 | 200°C | >200°C | Petrol | Crude oil | ||
| T4 | 135°C | >135°C | Ether | Ethyl ether | ||
T5 – 100°C, T6 – 85°C not available
Explosion group: The danger increases from explosion group II A to II C. The higher group includes the lower ones (e.g., II C includes II B and II A).
The customer must always specify the ignition temperatures of the substances.
5. Type of ignition protection
The following types of protection apply to non-electrical equipment in potentially explosive atmospheres:
| Identification | Description | Standardization |
|---|---|---|
| fr | Flow restricting enclosure | EN13463-2 |
| d | Frameproof enclosure | EN13463-3 |
| g | Intrinsic safety | EN13463-4 |
| c | Safety design (structural safety) | EN13463-5 |
| b | Control of ignition sources | EN13463-6 |
| p | Over pressure encapsulation | EN13463-7 |
| k | Liquid immersion | EN13463-8 |
Executable type of ignition protection from ALBERT: c, ck, (for Zone 1 und 2 ck)
6. labeling (example)
![]() |
II | 2 | G | ck | T4 |
| II | 2 | D | ck | 135°C | |
| Ex-marking | Device group | Category | Group of substances | Type of ignition protection | Temperature class |
| 2b | 2b | 2b | 5 | 3 |
7. Important:
Non-compliance with the operating instructions will invalidate the declaration of conformity 94/9/EG!